BACKGROUND

Electrode positioning directly influences the interpretation and diagnostic quality of ECG recordings. While current solutions mainly focus on detecting lead swaps in standard full-lead configurations, the growing adoption of portable and reduced-lead devices underscores the need for effective methods to identify and quantify electrode misplacement in various settings.

METHODS

We developed and evaluated an end-to-end, personalized, uncertainty-aware framework that took ECG waveforms as input and automatically detected and estimated potential electrode misplacement, using an annotated dataset of 4608 Mayo Clinic 12-lead ECGs. The pipeline combined a deep convolutional encoder to identify the lead source area with a regression head that leveraged the learned representation to estimate misplacement direction and magnitude. It also incorporated patient-specific ECG morphology for personalization and integrated an uncertainty quantification mechanism based on Monte Carlo dropout to enhance decision confidence.

RESULTS

The proposed method achieved over 94% classification accuracy in detecting the lead source area and estimated lead misplacement with a mean absolute error (MAE) of 2.2 cm. Incorporating personalized information enhanced results, reaching 97.5% accuracy and an MAE of 2.0 cm, while also largely maintaining performance for ECG determinations such as myocardial infarction and atrial fibrillation. The uncertainty-aware layer further reduced false corrections by flagging unfamiliar or ambiguous cases, boosting accuracy to 98.6% and lowering the MAE to 1.8 cm.

CONCLUSION

This study introduced a practical solution to improve ECG lead placement accuracy, enabling self-validating lead positioning that can enhance diagnostic reliability and support broader adoption of ECG technology in both clinical and decentralized care.

Для цитирования: Rafiei Alireza, Dwivedi Trisha, Xue Joel, Schlesinger Daphne E, Katebi Nasim, Albert David E, Clifford Gari D. Toward self-validating ECG Systems: A personalized, uncertainty-aware approach for detecting and estimating lead misplacement.. Journal of electrocardiology. 2026. DOI: 10.1016/j.jelectrocard.2026.154204.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.