Therapeutic drug monitoring · 2010

A novel HPLC method for quantification of 10 antiepileptic drugs or metabolites in serum/plasma using a monolithic column.

Сравнительное исследованиеСтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Heideloff Courtney, Bunch Dustin R, Wang Sihe

Аннотация

Therapeutic drug monitoring of antiepileptic drugs (AEDs) is important in maximizing the therapeutic response while minimizing the adverse effects. High-performance liquid chromatography (HPLC) is the most commonly used technique for this purpose. Recently, commercial monolithic columns were introduced, which consist of a single rod of fused silica or polymer. The objective of this work was to develop a simple and fast method to quantify 10 commonly measured AEDs or metabolites [carbamazepine, carbamazepine-10,11-epoxide, felbamate, lamotrigine, 10,11-dihydro-10-hydroxy-carbamazepine (active metabolite of oxcarbazepine), pentobarbital, phenobarbital, phenytoin, primidone, and zonisamide] in serum/plasma by HPLC using a reverse-phase monolithic column. Serum/heparin plasma (100 microL) was mixed with an internal standard solution (5-ethyl-5-p-tolylbarbituric acid in methanol, 250 microL). After centrifugation at 15,500 g for 10 minutes, 15 microL of supernatant was injected into a monolithic column. The analytes were eluted with an isocratic solution of 0.1 M, pH 6.5, phosphate buffer:methanol:acetonitrile (77:20:3), monitored at 210 nm. The chromatography time was 16 minutes. The method was linear from 0.4-4.9 to 21.2-190.9 microg/mL depending on the analytes with analytical recovery of 80%-114%. The inter- and intra-assay coefficients of variation were <8% in 3 levels of serum-based controls for all the analytes. No significant carryover was observed. Commercial controls containing >100 therapeutic drugs and common endogenous substances were tested and showed no interference. Comparison studies for 6 AEDs or metabolites were performed against commercial HPLC methods. Three AEDs were compared with Food and Drug Administration-approved immunoassays. All comparisons had R > 0.96 with slope ranging from 0.86 to 1.20. This is a simple and fast HPLC method suitable for measuring the 10 AEDs or metabolites. The use of the monolithic column resulted in increased sensitivity, better resolution, and a shorter analytical time compared with a regular C18 column.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты