DOI 10.1136/bmjophth-2019-000302
Evaluation of optic canal anatomy and symmetry using CT.
Аннотация
OBJECTIVE
We aim to describe the anatomy and symmetry patterns of the optic canal in patients having undergone maxillofacial CT imaging.
METHODS
In this retrospective chart review, we included all patients who received sinus and maxillofacial CT at the University of North Carolina hospitals between 2008 and 2016, without facial or cranial fractures or other medical conditions that would affect optic canal size. We measured the length of ≥75% enclosed canal, minimum cross-sectional area and minimum diameter bilaterally using iNtuition TeraRecon (Durham, North Carolina) and compared bilateral symmetry using a 20 % difference threshold. Each parameter above was compared among white, black, non-white and non-black patients.
RESULTS
Of 335 patients, the mean canal length was 5.61±2.22 mm. The mean minimum area was 11.84±3.11 mm2. The mean minimum diameter was 3.28±0.55 mm. A total of 39.4% (132/335) of patients had asymmetric canal lengths, 18.8% (63/335) had asymmetric minimum areas, and 12.5% (42/335) had asymmetric minimum diameters. No differences were found between racial groups. The right optic canal was larger than the left (right: 12.12 mm vs left: 11.55 mm, p<0.0001).
CONCLUSION
Optic canal asymmetry is not uncommon. It may affect risk of papilloedema severity, explain cases of unilateral or asymmetric papilloedema and possibly asymmetric glaucoma.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.