Referencing of markerless CT data sets with cone beam subvolume including registration markers to ease computer-assisted surgery - a clinical and technical research.

Essig Harald, Rana Majeed, Kokemueller Horst, Zizelmann Christoph, von See Constantin, Ruecker Martin, Tavassol Frank, Gellrich Nils-Claudius

СтатьяПеревод в очереди

Аннотация

BACKGROUND

As a prerequisite in navigation-assisted surgery, a three-dimensional image data set with registration marker is necessary. Often patients are presented, not being aware of facing a computer-assisted surgical intervention (CAS), with an already performed computed tomography (CT) data set without marker. The aim of this study was to evaluate the accuracy of a new method which allows performing CAS by enhancing the initial markerless data set with a marked subvolume gained by cone beam (CBCT) scan.

METHODS

Therefore four registration markers are inserted and afterwards the patient is strongly limited to the field of interest scanned by CBCT scan (marked data set). Superimposed with the initial data set, a data set with reference markers and with full information is obtained. Registration procedure was performed with group A (25 patients, superimposed marked CBCT scan) and group B (25 patients, initially marked CT scan) using BrainLab® navigation by two observers and overall system accuracy was measured using the registration landmarks and additional intraoperative landmarks (tooth cusps).

RESULTS

Adequate image quality assumed, no significant difference between group A and B was detected. Enhancing an initially performed data set with registration marker by using a marked subvolume could improve the workflow for navigation-assisted surgery due to the availability of cone beam scan technology, provide excellent resolution with reduced metal artifacts nearby dental restorations, and reduce radiation dose for the patient.

CONCLUSION

Regarding the advantages of the new method which allows performing CAS by enhancing the initial markerless data set with a marked subvolume gained by cone beam (CBCT) scan, this technique will play a major part in navigation-assisted surgery and will address widespread general methodological solutions that are of great interest in multidisciplinary treatment.

Для цитирования: Essig Harald, Rana Majeed, Kokemueller Horst, Zizelmann Christoph, von See Constantin, Ruecker Martin, Tavassol Frank, Gellrich Nils-Claudius. Referencing of markerless CT data sets with cone beam subvolume including registration markers to ease computer-assisted surgery - a clinical and technical research.. The international journal of medical robotics + computer assisted surgery : MRCAS. 2012. DOI: 10.1002/rcs.1444.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.