MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-025-07214-5

Медицинская библиотека · BMC oral health · 2025

Impact of framework material, cantilever design, and wing configuration on stress distribution in patient specific additively manufactured subperiosteal jaw implants: a 3D finite element analysis.

Canko Gokhan, Doganay Ozyilmaz Ozge

СтатьяПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: Recent advancements in digital technology have revolutionized implant dentistry, particularly with additively manufactured subperiosteal jaw implants (AMSJIs). These implants allow patient-specific designs that adapt to anatomical requirements. However, optimizing stress distribution remains a challenge.

PURPOSE: This study evaluated the stress distribution in AMSJIs and surrounding bone by analyzing different framework materials (PEEK and Co-Cr), anterior wing designs (I- and Y-shaped), and cantilever extensions using three-dimensional finite element analysis.

METHODS

A model was created from a patient with an atrophic, edentulous maxilla. Biomechanical evaluation of eight maxillary implant scenarios was performed under a 200 N force applied at a 45° oblique angle. Stress distribution in the bone, implants, screws, and prosthetic frameworks, as well as prosthetic displacement, was analyzed.

RESULTS

The lowest implant stress (444.5 MPa) was observed in the Co-Cr group without a cantilever using an I-shaped design, whereas the highest stress (623.0 MPa) occurred in the Co-Cr group with a cantilever using a Y-shaped design. Prosthetic displacement was greater in cantilevered groups, with PEEK exhibiting more displacement than Co-Cr.

CONCLUSIONS

The optimal stress distribution was achieved with the I-shaped design without a cantilever, using Co-Cr. Stress levels were significantly influenced by framework material, wing design, and cantilever presence, underscoring the importance of design and material selection.

CLINICAL SIGNIFICANCE: While stress remained within physiological limits in all cases, avoiding cantilevers and selecting a rigid material can optimize Y-shaped designs. PEEK demonstrated favorable properties in cantilevered designs, but its long-term effects on soft tissue and implants warrant further clinical trials.

Для цитирования: Canko Gokhan, Doganay Ozyilmaz Ozge. Impact of framework material, cantilever design, and wing configuration on stress distribution in patient specific additively manufactured subperiosteal jaw implants: a 3D finite element analysis.. BMC oral health. 2025. DOI: 10.1186/s12903-025-07214-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.