MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.0c03497

Медицинская библиотека · Analytical chemistry · 2020

Ultrasensitive Photoelectrochemical Assay for DNA Detection Based on a Novel SnS2/Co3O4 Sensitized Structure.

Long Dan, Li Mengjie, Wang Haihua, Wang Haijun, Chai Yaqin, Li Zhaohui, Yuan Ruo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this work, an ultrasensitive photoelectrochemical (PEC) assay was established for sensitive DNA detection based on a novel SnS2/Co3O4 sensitized structure as a photoactive matrix and benzo-4-chlorohexadienone (4-CD) precipitate as a signal quencher. Noticeably, the photoelectric conversion efficiency of the SnS2/Co3O4 sensitized structure was dramatically enhanced due to the effective sensitization of Co3O4 toward SnS2, thus attaining an intense photocurrent response, which was sixfold higher than that of pristine SnS2. Additionally, with the assistance of Nt.BstNBI enzyme-assisted target cycling process, a limited amount of target DNA (a fragment of p53 gene) could be converted into extensive output DNA, which could hybridize with capture DNA to yield abundant DNA duplex for loading mimetic enzyme manganese porphyrin (MnPP). Subsequently, 4-chloro-1-naphthol (4-CN) could be catalyzed to form 4-CD precipitate by MnPP on the modified electrode surface with the existence of H2O2. Then, the 4-CD precipitate severely hampered electron transfer, causing a prominently diminished photocurrent response for DNA determination. The elaborated PEC assay not only extended the application of SnS2 in the PEC biosensing field but also manifested a wide linear range of 100 aM to 1 nM with a low detection limit of 30 aM, exhibiting enormous potential for the detection of various biomarkers or other targets in bioanalysis and disease diagnosis fields.

Для цитирования: Long Dan, Li Mengjie, Wang Haihua, Wang Haijun, Chai Yaqin, Li Zhaohui, Yuan Ruo. Ultrasensitive Photoelectrochemical Assay for DNA Detection Based on a Novel SnS2/Co3O4 Sensitized Structure.. Analytical chemistry. 2020. DOI: 10.1021/acs.analchem.0c03497.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.