BACKGROUND AND PURPOSE: Clonus arising from plantar flexor hyperreflexia is a phenomenon that is commonly observed in persons with spastic hypertonia. We assessed the temporal components of a biomechanical measure to quantify ankle clonus, and validated these in persons with spasticity due to spinal cord injury.

METHODS

In 40 individuals with chronic (>1 year) spinal cord injury, we elicited ankle clonus using a standardized mechanical perturbation (drop test). We examined reliability and construct validity of 2 components of the drop test: clonus duration (timed with a stopwatch) and number of oscillations in the first 10-second interval (measured via optical motion capture). We compared these measures to the Spinal Cord Assessment Tool for Spastic reflexes (SCATS) clonus score and H-reflex/M-wave (H/M) ratio, a clinical and electrophysiologic measure, respectively.

RESULTS

Intra- and interrater reliability of clonus duration measurement was good [intraclass correlation coefficient, ICC (2, 1) = 1.00]; test-retest reliability was good both at 1 hour [ICC (2, 2) = 0.99] and at 1 week [ICC (2, 2) = 0.99]. Clonus duration was moderately correlated with SCATS clonus score (r = 0.58). Number of oscillations had good within-session test-retest reliability [ICC (2, 1) > 0.90] and strong correlations with SCATS clonus score (r = 0.86) and soleus H/M ratio (r = 0.77).

DISCUSSION AND

CONCLUSIONS

Clonus duration and number of oscillations as measured with a standardized test are reliable and valid measures of plantar flexor hyperreflexia that are accessible for clinical use. Tools for objective measurement of ankle clonus are valuable for assessing effectiveness of interventions directed at normalizing reflex activity associated with spasticity.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, http://links.lww.com/JNPT/A179).

Для цитирования: Manella Kathleen J, Roach Kathryn E, Field-Fote Edelle C. Temporal Indices of Ankle Clonus and Relationship to Electrophysiologic and Clinical Measures in Persons With Spinal Cord Injury.. Journal of neurologic physical therapy : JNPT. 2017. DOI: 10.1097/npt.0000000000000197.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.