In an audit of 68 scaphoid fractures with delayed and non-union that had been internally fixed using the Herbert bone screw, it was found that 39 had a significant fault in screw position. Poor intra-operative imaging was a major contributing factor. An anatomical and radiological study was therefore performed to evaluate which views were necessary in order to be confident about screw position. We recommend a minimum of four views. To display the proximal pole, an ulnar deviated postero-anterior (PA) view and true lateral; and to display the distal pole, a semi-pronated and semi-supinated view.