An experience with Goel-Harms C1-C2 fixation for type II odontoid fractures.
Аннотация
OBJECTIVE
Type II odontoid fractures need surgical stabilization for disabling neck pain and instability. Anterior odontoid screw fixation is a well-known technique. However, certain patients require posterior fixation. We present our surgical results and experiences with nine cases managed by the Goel-Harms technique.
MATERIALS AND
METHODS
This is a retrospective review of nine patients operated on between January 2019 and December 2021 for Type II odontoid fractures with posterior fixation technique. Their clinical profile was collected from case files. The radiological data were retrieved from radiology archives. The indications for surgery were instability and refractory neck pain. The surgical decision for posterior fixation was guided by fracture morphology.
RESULTS
The mean age of presentation was 37.22 ± 9.85 years. Seven patients had Type II, and two had Type IIa odontoid fracture. All patients presented with unbearable neck pain. One patient had a quadriparesis. The fracture line was anterior-inferior sloping in six, posterior-inferior sloping in two, and transverse in one case. The anterior-posterior displacement of fracture ranged from 0 to 7 mm (mean 2.44 ± 2.18 mm). Partial transverse ligament tear without the Atlanto Axial Dislocation was present in three patients. The C1-C2 joint distraction was required in five cases. C1-C2 joint spacer was required in two cases. Following surgery, neck pain was relieved in all cases. Complete fracture alignment was achieved in eight patients. There were no postoperative complications. At the mean follow-up of 16.22 ± 9.61 months, there was no implant failure.
CONCLUSIONS
Posterior C1-C2 fixation by the Goel-Harms technique is an excellent alternative to anterior fixation in selected cases.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.