MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mrgentox.2023.503639

Медицинская библиотека · Mutation research. Genetic toxicology and environmental mutagenesis · 2023

A panel of visual bacterial biosensors for the rapid detection of genotoxic and oxidative damage: A proof of concept study.

Hui Chang-Ye, Hu Shun-Yu, Yang Xue-Qin, Guo Yan

СтатьяПеревод в очереди

Аннотация

The emergence of new compounds during the past decade requires a high-throughput screening method for toxicity assay. The stress-responsive whole-cell biosensor is a powerful tool to evaluate direct or indirect damages of biological macromolecules induced by toxic chemicals. In this proof-of-concept study, nine well-characterized stress-responsive promoters were first selected to assemble a set of blue indigoidine-based biosensors. The PuspA-based, PfabA-based, and PgrpE-based biosensors were eliminated due to their high background. A dose-dependent increase of visible blue signal was observed in PrecA-, PkatG-, and PuvrA-based biosensors, responsive to potent mutagens, including mitomycin and nalidixic acid, but not to genotoxic lead and cadmium. The PrecA, PkatG, and Ppgi gene promoters were further fused to a purple deoxyviolacein synthetic enzyme cluster. Although high basal production of deoxyviolacein is unavoidable, an enhanced visible purple signal in response to mitomycin and nalidixic acid was observed as dose-dependent, especially in PkatG-based biosensors. The study shows that a set of stress-responsive biosensors employing visible pigment as a reporter is pre-validating in detecting extensive DNA damage and intense oxidative stress. Unlike widely-used fluorescent and bioluminescent biosensors, the visual pigment-based biosensor can become a novel, low-cost, mini-equipment, and high-throughput colorimetric device for the toxicity assessment of chemicals. However, combining multiple improvements can further improve the biosensing performance in future studies.

Для цитирования: Hui Chang-Ye, Hu Shun-Yu, Yang Xue-Qin, Guo Yan. A panel of visual bacterial biosensors for the rapid detection of genotoxic and oxidative damage: A proof of concept study.. Mutation research. Genetic toxicology and environmental mutagenesis. 2023. DOI: 10.1016/j.mrgentox.2023.503639.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.