MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13256-020-02465-y

Медицинская библиотека · Journal of medical case reports · 2020

Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report.

Chiocchi Marcello, Spiritigliozzi Luigi, Di Tosto Federica, Benelli Leonardo, D'Errico Francesca, Presicce Matteo, Pugliese Luca, Ricci Francesca, De Stasio Vincenzo, Di Donna Carlo, Pasqualetto Monia, Colella Dionisio Ferdinando, Floris Roberto

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

An ascending aortic pseudoaneurysm is a severe and rare complication following cardiothoracic surgery. This case report demonstrates its possible misinterpretation and the consequent importance of multidisciplinary evaluation.

CASE PRESENTATION: We present a case of an 18-year-old Caucasian man with Marfan syndrome who developed an ascending aortic pseudoaneurysm about 1 year after undergoing cardiac surgery with the Bentall procedure. Computed tomographic examination of the thoracic aorta and positron emission tomography-computed tomography initially suggested a lymphomatous pathology. However, these imaging results were in contrast to the transesophageal echocardiogram and the laboratory data that showed negative results for hematological pathology. A second computed tomographic scan redirected the diagnosis toward a pseudoaneurysm.

CONCLUSION

This case demonstrates the utility of close communication and interdisciplinary consultation between cardiovascular radiologists and the cardiac surgery team, which are mandatory in order to maximize their diagnostic skills in identifying postoperative complications.

Для цитирования: Chiocchi Marcello, Spiritigliozzi Luigi, Di Tosto Federica, Benelli Leonardo, D'Errico Francesca, Presicce Matteo, Pugliese Luca, Ricci Francesca, De Stasio Vincenzo, Di Donna Carlo, Pasqualetto Monia, Colella Dionisio Ferdinando, Floris Roberto. Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report.. Journal of medical case reports. 2020. DOI: 10.1186/s13256-020-02465-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.