MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00266-013-0244-8

Медицинская библиотека · Aesthetic plastic surgery · 2013

Correction of asymmetric pectus excavatum using a virtually designed silicone implant.

Wallmichrath Jens, Baumeister Ruediger G, Giunta Riccardo E, Holzbach Thomas, Frick Andreas

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

An extended asymmetric funnel chest deformity with the breast gland located in the thoracic mold can lead to a fictitious aplasia of the breast. The authors termed this condition "pseudo-Amazon syndrome" because the breast tissue and the pectoralis muscle are fully developed.

METHODS

This report presents a detailed technical approach to the fabrication of a precise-fitting custom-made silicone implant. The design of the implant was achieved using a computed tomography (CT) data set and rapid prototyping. The volumes of the "hidden" and the normal breasts measured preoperatively by processing the CT data were similar. These volumes were compared with the breast volumes measured by three-dimensional photography 4 years postoperatively to assess the predictability of the volume congruency. The silicone implant was surgically placed in the epicostal plane and extended almost over the right hemithorax.

RESULTS

The implantation was performed without the necessity of further trimming. Both the surgeon and the patient rated the aesthetic and functional long-term result as good in terms of symmetry and the possibility of exercise without restrictions. The final breast volume of the surgically treated side was 95 % of the volume of the normal contralateral breast.

CONCLUSION

The described method reduces the operation time and the operative trauma by primary implant fit. However, the method is rather elaborate and the production process is expensive. This in turn reduces the generation of proceeds to a minimum.

LEVEL OF EVIDENCE V: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Для цитирования: Wallmichrath Jens, Baumeister Ruediger G, Giunta Riccardo E, Holzbach Thomas, Frick Andreas. Correction of asymmetric pectus excavatum using a virtually designed silicone implant.. Aesthetic plastic surgery. 2013. DOI: 10.1007/s00266-013-0244-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.