MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2185-8472

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2023

Imaging of Amyloid-Related Imaging Abnormalities (ARIA).

Urbach Horst, Linn Jennifer, Hattingen Elke, Fiebach Jochen

СтатьяПеревод в очереди

Аннотация

Patients with Alzheimer's disease (AD) can now be treated with monoclonal antibodies aiming at clearing amyloid plaques from the brain parenchyma. Weeks after initiation of this drug therapy, patients may develop so-called amyloid-related imaging abnormalities (ARIA) on MRI. ARIA comprise vasogenic edema and leptomeningeal effusions (ARIA-E) as well as microbleeds and superficial hemosiderosis (ARIA-H). The prevalence is drug- and dose-dependent (up to 40 % of patients), the apolipoprotein E4 variant and concomitant cerebral amyloid angiopathy (CAA) increase the risk. With regard to MRI characteristics, ARIA strongly resembles the so-called inflammatory subtype of CAA (CAA-ri). While patients with CAA-ri are typically detected due to symptoms such as headaches, lethargy, confusion, and rarely epileptic seizures, around 20 % of ARIA patients show symptoms. Management of ARIA is not yet clearly established. In asymptomatic patients, discontinuation of the drug might be sufficient. KEY POINTS:   · Amyloid-related imaging abnormalities (ARIA) occur in around 20 % of patients who are treated with monoclonal antibodies against amyloid β.. · There are 2 types: ARIA-E (edema effusion) und ARIA-H (hemorrhage).. · Depending on the severity, therapy with monoclonal antibodies is either interrupted or finished.. CITATION FORMAT: · Urbach H, Linn J, Hattingen E et al. Imaging of Amyloid-Related Imaging Abnormalities (ARIA). Fortschr Röntgenstr 2024; 196: 363 - 369.

Для цитирования: Urbach Horst, Linn Jennifer, Hattingen Elke, Fiebach Jochen. Imaging of Amyloid-Related Imaging Abnormalities (ARIA).. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2023. DOI: 10.1055/a-2185-8472.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.