MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/ejhpharm-2023-003689

Медицинская библиотека · European journal of hospital pharmacy : science and practice · 2024

Y-site simulation compatibility study of 10% calcium salts with various injectable solutions during toxicological resuscitation.

Hamelin Arianne, Thompson-Desormeaux Félix, Elliott Audrée, Friciu Mihaela, Forest Jean-Marc, Leclair Gregoire

СтатьяПеревод в очереди

Аннотация

PURPOSE: To determine the physical compatibility of 10% calcium chloride and 10% calcium gluconate in combination with injectable solutions, administered in the paediatric and adult intensive care unit setting during toxicological resuscitation involving calcium channel blockers and beta-blockers.

METHODS

Forty-eight combinations were prepared at room temperature, including the following products: calcium chloride, calcium gluconate, insulin, epinephrine, norepinephrine, highly concentrated dextrose solution, sodium chloride, Plasma-Lyte A and Ringer's lactate. A visual evaluation at times 0, 1, 4, 24, 48 and 72 hours and a particle count test with the LS-20 particle counter at times 0, 4, 24 and 72 hours were performed. The admixtures were considered incompatible if there was a precipitate, a colour change, turbidity, viscosity or a gas formation. The stability of calcium salts was also tested in empty IV bags and syringes by the particle count test.

RESULTS

All drug mixtures were found to be compatible by visual evaluation and using the particle counter based on United States Pharmacopoeia chapter 788 (USP<788>) specifications. Calcium salts were compatible with insulin and vasopressors in the tested combinations. The stability of 10% calcium salts in empty IV bags and polypropylene syringes was demonstrated for up to 48 hours at room temperature.

CONCLUSION

All the combinations tested were physically compatible for up to 72 hours at room temperature. Clinical use of calcium salt infusions, at an undiluted concentration, in combination with these injectable solutions in a toxicological resuscitation context is considered clinically acceptable.

Для цитирования: Hamelin Arianne, Thompson-Desormeaux Félix, Elliott Audrée, Friciu Mihaela, Forest Jean-Marc, Leclair Gregoire. Y-site simulation compatibility study of 10% calcium salts with various injectable solutions during toxicological resuscitation.. European journal of hospital pharmacy : science and practice. 2024. DOI: 10.1136/ejhpharm-2023-003689.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.