Transcatheter Closure of a Patent Ductus Arteriosus Using a Piccolo Duct Occluder.

Deb Pranjit, Benerjee Anindya, Som Tapas, Barik Ramachandra

Клинический случайСтатьяПеревод в очереди

Аннотация

Transcatheter closure of patent ductus arteriosus (PDA) is feasible in low-birth-weight infants. A female baby was born prematurely with a birth weight of 924 g. She had a PDA measuring 3.7 mm. She was dependent on positive pressure ventilation for congestive heart failure in addition to the heart failure medications. She could not be discharged from the hospital even after 79 days of birth, and even though her weight reached 1.9 kg in the neonatal intensive care unit. We attempted to plug the PDA using an Amplatzer Piccolo Occluder, but the device failed to anchor. Then, the PDA was plugged using a 4-6 Amplatzer Duct Occluder using a 6-Fr sheath which was challenging.