MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.09.18.26363360

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2026

Low-Intensity Focused Ultrasound of the Amygdala in Depression and Anxiety: A First-in-Human Active-Controlled Trial.

Arulpragasam Amanda R, van 't Wout-Frank Mascha, Berlow Yosef A, Aiken Emily, Gorbatov Alison, Van Patten Ryan, Gillotti Julia G, Swearingen Hannah R, Faucher Christiana R, Adams Hannah, McLaughlin Nicole C R, Liberzon Israel, Barredo Jennifer, Correia Stephen, Greenberg Benjamin, Philip Noah S

СтатьяПрепринтПеревод в очереди

Аннотация

BACKGROUND

Low-intensity focused ultrasound (FUS) offers a noninvasive method for directly modulating deep brain structures with millimeter-scale precision, potentially addressing a major limitation of existing noninvasive neuromodulation approaches. The amygdala is a key node in affective neurocircuitry and a compelling target for psychiatric intervention. We conducted a first-in-human active controlled trial (NCT05147142) of amygdala-targeted FUS in patients with major depressive disorder, examining safety and target engagement.

METHODS

Ten participants with major depressive disorder completed a single-blind randomized crossover trial with blinded symptom ratings, comparing imaging-guided FUS targeting the right amygdala versus left primary somatosensory cortex as an active control. FUS comprised two 10-minute applications within diagnostic ultrasound safety limits. Primary outcomes were safety and target engagement assessed with BOLD-fMRI during sonication, post-sonication arterial spin labeling (ASL) and resting-state functional connectivity. Secondary and exploratory outcomes included symptom change and imaging-symptom relationships.

RESULTS

Nine participants completed both sessions. No serious adverse events occurred; neurological, neuropsychological, and MRI safety assessments were unremarkable. Adverse events were more frequent after amygdala than control sonication (p=0.028); one participant experienced clinical worsening following amygdala sonication and required monitoring. Amygdala sonication produced greater perfusion change in the targeted amygdala compared to the control region (p<0.001), and ipsilateral hippocampus (p<0.001). BOLD-fMRI during sonication demonstrated engagement of ventromedial prefrontal and rostral anterior cingulate regions, while post-sonication resting-state connectivity decreased between basolateral amygdala and sensorimotor regions (corrected ps<0.05). Symptom improvement did not differ between conditions, but exploratory imaging-symptom relationships were significant. Spontaneous reports of calm, clarity, or lightness occurred after amygdala but not control sonication (p<0.001).

CONCLUSIONS

Amygdala-targeted FUS produced anatomically specific, multimodal evidence of neuromodulation relative to active control, with a manageable safety profile. Convergent target and circuit-level signals support further development of FUS as a precision approach for modulating deep brain targets in psychiatric disorders.

Для цитирования: Arulpragasam Amanda R, van 't Wout-Frank Mascha, Berlow Yosef A, Aiken Emily, Gorbatov Alison, Van Patten Ryan, Gillotti Julia G, Swearingen Hannah R, Faucher Christiana R, Adams Hannah, McLaughlin Nicole C R, Liberzon Israel, Barredo Jennifer, Correia Stephen, Greenberg Benjamin, Philip Noah S. Low-Intensity Focused Ultrasound of the Amygdala in Depression and Anxiety: A First-in-Human Active-Controlled Trial.. medRxiv : the preprint server for health sciences. 2026. DOI: 10.64898/2026.09.18.26363360.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.