Annals of vascular surgery · 2015
Open Treatment of Blunt Injuries of Supra-Aortic Branches: Case Series.
Клинический случайСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sladojevic Milos, Markovic Miroslav, Ilic Nikola, Pejkic Sinisa, Banzic Igor, Djoric Predrag, Koncar Igor, Tomic Ivan, Davidovic Lazar
Аннотация
BACKGROUND: Blunt injuries of the supra-aortic branches are rare entity, and majority of patients die before arrival at the hospital. Those who arrive alive require complex and fast procedure that requires sternotomy. We report 3 successfully managed cases.
CASE REPORTS: We report 3 patients with injury of supra-aortic branches. One was treated urgently due to longitudinal rupture on the posterior wall of innominate artery after car accident, and another 2 had chronic false aneurysm located at the very orifice of the right subclavian and left common carotid artery. In first and second patient bypass grafting with a hand-made, Y-shaped, 8-mm Dacron graft from the ascending aorta to the right common carotid and proximal right subclavian artery were performed, whereas in last 1 bypass grafting from the ascending aorta to the cervical part of the left common carotid artery was performed. In our facility, there were no possibilities for any endovascular treatment.
CONCLUSIONS: When endovascular technology is not available, open surgical repair of blunt injuries of supra-aortic vessels can be performed without complications. No matter to that, endovascular and hybrid procedures should be considered whenever possible.
CASE REPORTS: We report 3 patients with injury of supra-aortic branches. One was treated urgently due to longitudinal rupture on the posterior wall of innominate artery after car accident, and another 2 had chronic false aneurysm located at the very orifice of the right subclavian and left common carotid artery. In first and second patient bypass grafting with a hand-made, Y-shaped, 8-mm Dacron graft from the ascending aorta to the right common carotid and proximal right subclavian artery were performed, whereas in last 1 bypass grafting from the ascending aorta to the cervical part of the left common carotid artery was performed. In our facility, there were no possibilities for any endovascular treatment.
CONCLUSIONS: When endovascular technology is not available, open surgical repair of blunt injuries of supra-aortic vessels can be performed without complications. No matter to that, endovascular and hybrid procedures should be considered whenever possible.
Предметные рубрики MeSH
AdultAneurysm, FalseAngiography, Digital SubtractionAortaAortic AneurysmAortographyBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationHumansMaleMiddle AgedMultidetector Computed TomographyPolyethylene TerephthalatesPolytetrafluoroethyleneProsthesis DesignThoracic InjuriesTreatment OutcomeVascular System InjuriesWounds, Nonpenetrating