MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/01477447-20140626-53

Медицинская библиотека · Orthopedics · 2014

Wake-up test in total hip arthroplasty with high-riding developmental dysplasia.

Chen Kun-Hui, Wang Hsin-Yi, Sung Chun-Sung, Wu Po-Kuei, Chen Cheng-Fong, Liu Chien-Lin, Chen Wei-Ming

СтатьяПеревод в очереди

Аннотация

Total hip arthroplasty (THA) for patients with Crowe type IV developmental dysplasia of the hip is technically challenging. This group of patients has a higher incidence of nerve injury during THA. Although neurophysiologic intraoperative monitoring has been developed to provide nerve monitoring, it is not always available. The wake-up test has been used for intraoperative spinal cord monitoring during major spinal surgery, but no study has reported the use of the wake-up test for neurologic monitoring during THA in patients with severe developmental dysplasia of the hip. The authors retrospectively reviewed 22 THA procedures in 20 patients with Crowe type IV developmental dysplasia of the hip who underwent the wakeup test during THA. In the current study, 1 patient could not dorsiflex her foot during the wake-up test. Therefore, the authors immediately reduced the length of limb lengthening by 1 cm. Postoperative drop foot and numbness occurred but resolved completely 2 months later. None of the patients who showed no deficits in motion of the feet during the intraoperative wake-up test had signs of postoperative nerve injury. In the current study, there was no false-positive or false-negative finding. The authors concluded that the wake-up test, which is simple, safe, and reliable, is a useful technique and a possible alternative to neurophysiologic intraoperative monitoring in checking nerve function during THA in patients with severe developmental dysplasia of the hip.

Для цитирования: Chen Kun-Hui, Wang Hsin-Yi, Sung Chun-Sung, Wu Po-Kuei, Chen Cheng-Fong, Liu Chien-Lin, Chen Wei-Ming. Wake-up test in total hip arthroplasty with high-riding developmental dysplasia.. Orthopedics. 2014. DOI: 10.3928/01477447-20140626-53.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.