Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2004

The cocoon sign: a potential sonographic pitfall in the diagnosis of twin - twin transfusion syndrome.

Quintero R A, Chmait R H

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To investigate the frequency and clinical importance of the cocoon sign in twin-twin transfusion syndrome (TTTS).

METHODS

Charts and ultrasound images of all pregnancies with TTTS that underwent selective laser photocoagulation of communicating vessels at our institution over a 1-year period were retrospectively reviewed for a cocoon sign. TTTS had been diagnosed and prospectively staged if monochorionicity was suspected and the maximum vertical pocket (MVP) of amniotic fluid in one gestational sac was >/=8 cm, while the MVP in the other gestational sac was </=2 cm. The cocoon sign was diagnosed when there was an ultrasound finding of a donor twin with severe oligohydramnios enveloped by dividing membranes and connected to the uterine wall by a laminar stalk of these membranes.

RESULTS

The cocoon sign was noted in 9/58 (15.5%) cases. There were no differences in gestational age and stage of TTTS upon presentation, gestational age at delivery or number of neonatal survivors between the groups of TTTS cases with and those without a cocoon sign. One patient in the cocoon group had been misdiagnosed because the donor twin's MVP was measured from the donor's tethered membranes to the posterior wall of the uterus within the recipient's sac.

CONCLUSIONS

The cocoon sign is present in at least 15% of patients with TTTS. Its recognition is important to avoid misdiagnosis of TTTS. The practical implications and potential complications of this sonographic sign are discussed.

Для цитирования: Quintero R A, Chmait R H. The cocoon sign: a potential sonographic pitfall in the diagnosis of twin - twin transfusion syndrome.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2004. DOI: 10.1002/uog.945.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.