Correlation of transthoracic echocardiography-derived pulmonary to systemic flow ratio with hemodynamically estimated left to right shunt in atrial septal defects.
Аннотация
BACKGROUND
Transthoracic echocardiographic (TTE) estimation of the pulmonary to systemic flow ratio (Qp/Qs) is routinely used in clinical practice and is included in the American Society of Echocardiography Guidelines. We sought to assess its real-world applicability with a particular focus on hemodynamically significant shunt lesions.
METHODS
Retrospective single institutional review of TTE's in patients with secundum atrial septal defect prior to cardiac catheterization (cath) from 2012 to 2018 was performed (n = 109), those with technically limited images for Qp/Qs calculation (n = 11) and those with time interval between TTE and cath >60 days were excluded (n = 14). Qp/Qs was calculated from stored clips by previously described methods and correlated with those obtained by oximetry. Patients were subdivided into two age groups <21 (Group 1) and ≥22 years (Group 2). TTE and cath methods for Qp/Qs estimation were compared using paired t-test, Pearson's correlation coefficient, and Bland-Altman plots.
RESULTS
Eighty-four subjects met inclusion criteria (age range 3-78 years). Group 1 n = 35; median age 10 years; Group 2 n = 49; median age 49 years. Transthoracic echocardiogram was performed 19.5 ± 15 days prior to cath. Mean Qp/Qs derived by cath and TTE were 2.09 ± 0.9 versus 2.54 ± 1.2 (P < 0.0001). Overall correlation was poor between the methods (r 2 = 0.32, P < 0.0001) and continued to be poor for Groups 1 and 2 (r 2= 0.24, P = 0.003 and r 2= 0.40, P < 0.0001 respectively). Bland-Altman plots demonstrated poor agreement between the predetermined limits of agreement (-0.5-1.5).
CONCLUSION
Transthoracic echocardiography estimated Qp/Qs, although routinely utilized in clinical practice, has poor correlation and agreement with oximetry-derived Qp/Qs. The test performs poorly in all age groups in detecting a hemodynamically significant shunt and tends to overestimate the degree of left to right shunt.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.