MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/sj.jp.7211034

Медицинская библиотека · Journal of perinatology : official journal of the California Perinatal Association · 2004

An amniotic fluid index < or =5 cm within 7 days of delivery in the third trimester is not associated with decreasing umbilical arterial pH and base excess.

Driggers Rita W, Holcroft Cynthia J, Blakemore Karin J, Graham Ernest M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine if an amniotic fluid index (AFI) < or =5.0 cm within 7 days of delivery in the third trimester is associated with decreasing umbilical arterial pH and base excess.

STUDY

DESIGN

Cases for this retrospective cohort study were all pregnancies > or =26 weeks with intact membranes and an AFI < or =5.0 cm within 7 days of delivery between 11/99 and 7/02. Multiple gestations, aneuploid, and anomalous fetuses were excluded. Controls with an AFI >5.0 cm within 7 days of delivery were matched to each case within 1 week by gestational age. For a control group with a mean+/-SD umbilical arterial pH of 7.26+/-0.07 and alpha=0.05, a sample size of 100 would have a power of 99% to detect a difference with a study group whose mean was 7.20. Data were compared using paired Student's t-test, Mann-Whitney, Fisher's exact, chi(2) and risk ratios with 95% confidence intervals.

RESULTS

In all, 131 neonates with an AFI < or =5.0 cm were matched to 131 controls with an AFI >5 cm. There was no difference in gestational age (37.6+/-3.0, 37.7+/-3.0 weeks) or birth weight (2897+/-810, 2762+/-788 g). There was no difference in umbilical artery pH (7.25+/-0.07, 7.26+/-0.07) or base excess (-3.32+/-2.59, -2.83+/-2.45 mmol/l), even in small for gestational age (SGA) infants in both groups. There was no difference in the number of SGA neonates, 5-minute Apgar <7, respiratory distress syndrome, necrotizing enterocolitis, or neurologic morbidity. Linear regression showed no correlation between AFI and either umbilical arterial pH (r=-0.00047, SE=0.001, p=0.63) or base excess (r=-0.029, SE=0.037, p=0.428).

CONCLUSION

An AFI < or =5.0 cm measured within 7 days of delivery in the third trimester is not associated with decreasing umbilical arterial pH and base excess.

Для цитирования: Driggers Rita W, Holcroft Cynthia J, Blakemore Karin J, Graham Ernest M. An amniotic fluid index < or =5 cm within 7 days of delivery in the third trimester is not associated with decreasing umbilical arterial pH and base excess.. Journal of perinatology : official journal of the California Perinatal Association. 2004. DOI: 10.1038/sj.jp.7211034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.