MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/1807-3107bor-2016.vol30.0027

Медицинская библиотека · Brazilian oral research · 2016

Volume of sealer in the apical region of teeth filled by different techniques: a micro-CT analysis.

Araújo Vanessa Lessa, Souza-Gabriel Aline Evangelista, Cruz Filho Antônio Miranda da, Pécora Jesus Djalma, Silva Ricardo Gariba

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The volume of sealer in the apical 1 mm of teeth filled using different techniques was evaluated by micro-commuted tomography (micro-CT). Sixty-four maxillary central incisors were prepared using NiTi rotary instruments. Teeth were randomly distributed into four groups according to root canal sealers (AH Plus, Endofill, Sealapex, and Sealer 26) and subdivided into two subgroups according to the filling techniques (active and passive lateral condensation; n = 8 each). Subsequently, teeth were examined using the 1174 SkyScan micro-CT device. Images were reconstructed using the NRecon software, and the sealer volume (mm3) in the apical region was analyzed using the two-way ANOVA and post-hoc Student-Newman-Keuls test (α = 0.05). The lowest volume of sealer was observed in teeth filled with Sealapex (0.100 ± 0.009) and Endofill (0.103 ± 0.010). The highest volume was observed in teeth filled with AH Plus (0.112 ± 0.008) and Sealer 26 (0.109 ± 0.018) (p > 0.05). Regarding the filling technique, a lower sealer volume was observed using the active lateral condensation technique compared with that using the passive lateral condensation technique (0.100 ± 0.010 vs. 0.111 ± 0.012) (p < 0.05). Therefore, the lowest volume of sealer was observed in teeth filled with Sealapex and Endofill using the active lateral condensation technique.

Для цитирования: Araújo Vanessa Lessa, Souza-Gabriel Aline Evangelista, Cruz Filho Antônio Miranda da, Pécora Jesus Djalma, Silva Ricardo Gariba. Volume of sealer in the apical region of teeth filled by different techniques: a micro-CT analysis.. Brazilian oral research. 2016. DOI: 10.1590/1807-3107bor-2016.vol30.0027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.