The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2018

Accuracy of the Bilicare™ transcutaneous bilirubinometer as the predischarge screening tool for significant hyperbilirubinemia in healthy term and late preterm neonates.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chokemungmeepisarn Peerathat, Tantiprabha Watcharee, Kosarat Shanika, Manopunya Satit

Аннотация

Background: The Bilicare™ is a new device that measures transcutaneous bilirubin (TcB) level at the ear pinna. There are only few studies which have evaluated its accuracy in clinical practice.Objective: This study aims to determine the accuracy of Bilicare™ as a predischarge screening tool in late preterm and term neonates and to define the optimal cutoff point for determining the need to measure total serum bilirubin (TSB).Methods: The 35 weeks' gestation or more and healthy neonates who underwent predischarge TSB measurement were enrolled. Bilicare™ TcB was measured within 30 minutes of blood sampling. Paired TcB and TSB data were analyzed.Results: We collected 214 paired samples. Mean age (SD) at TcB measurement was 57.17 (7.47) hours. Mean TSB (SD) was 9.79 (2.83) mg/dL. TcB showed a significant correlation with TSB (r = 0.84, r2 = 0.7). The mean difference (SD) between TcB and TSB was 0.7 (0.21) mg/dL (95%CI 0.49-0.91). TcB tended to overestimate TSB level at the TSB values of <12 mg/dL but underestimate at the higher TSB level. The accuracy of using TcB values to detect neonates who required phototherapy was 92.5%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 78.3, 94.2, 62.1, and 97.3%, respectively. If TcB +3 mg/dL was applied as a cutoff point, the sensitivity, specificity, PPV, and NPV were 100, 53.9, 20.7, and 100%, respectively.Conclusions: Bilicare™ TcB and TSB measurements were well correlated. The TcB level +3 mg/dL could detect all neonates who had significant hyperbilirubinemia requiring phototherapy during their birth hospitalization.