MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6sc01239f

Медицинская библиотека · Chemical science · 2026

Time-resolved image-guided Type-I photosensitization using a delayed fluorescent emitter.

Das Subhadeep, Mandal Arnab, Joshi Pradyumna Ajit, K Shradha V T, McDonald Peter W, Métivier Rémi, Mishra Ram Kumar, Patra Abhijit

СтатьяПеревод в очереди

Аннотация

The development of next-generation image-guided thermally activated delayed fluorescent photosensitizers requires high quantum yield, organelle specificity, and low oxygen dependence to enable effective photodynamic therapy. A subtle balance between the opposing requirements of strong radiative transition for high-contrast imaging and efficient nonradiative decay for reactive oxygen species generation remains a key challenge for time-resolved image-guided photodynamic therapy. In this study, we present a lipid droplet (LD) targeting delayed fluorescent probe, based on substituted keto-coumarin, DCBP, and its water-dispersible nanoparticles. DCBP in solution and aqueous dispersions exhibits long-lived emission and possesses an optimum excited-state oxidation potential, promising for time-resolved image-guided Type-I photosensitization. The intrinsic hydrophobicity of DCBP nanoparticles promotes specificity towards lipid droplets, exhibiting pronounced phototoxicity under normoxic and hypoxic conditions via dual-mode photosensitization through superoxide anion radical generation and NADH oxidation. Furthermore, polymer-encapsulated DCBP nanoparticles (DP-NPs) enable time-resolved luminescence imaging of lipid-rich fat bodies in Drosophila larvae at the microsecond scale, followed by effective image-guided photosensitization. This work creates exciting yet underexplored avenues for time-resolved imaging using Type-I delayed fluorescent photosensitizers for targeted intracellular image-guided photodynamic therapy.

Для цитирования: Das Subhadeep, Mandal Arnab, Joshi Pradyumna Ajit, K Shradha V T, McDonald Peter W, Métivier Rémi, Mishra Ram Kumar, Patra Abhijit. Time-resolved image-guided Type-I photosensitization using a delayed fluorescent emitter.. Chemical science. 2026. DOI: 10.1039/d6sc01239f.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.