Медицинская библиотека · Journal of AOAC International · 2018

Single-Laboratory Validation of a Gas Chromatographic Method of Direct Determination of Volatile Compounds in Spirit Drinks: Need for an Improved Interlaboratory Study.

Charapitsa Siarhei V, Sytova Svetlana N, Korban Anton L, Sobolenko Lidia N

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Background

The quality and safety control of an alcoholic drink is mainly the establishment of its chemical content, particularly the quantity of volatile compounds.

Objective

A single-laboratory validation of a gas chromatographic method of direct determination of volatile compounds in spirit drinks was conducted. The discussed method applies ethanol, the major volatile component of an alcoholic beverage, as an internal standard. Possible algorithms of method validation based on interlaboratory study were proposed and described.

Methods

Seven standard solutions of the following volatile compounds were prepared gravimetrically in 40% (v/v) water-ethanol solution: acetaldehyde, methyl acetate, ethyl acetate, methanol, 2-propanol, 1-propanol, isobutanol, 1-butanol, and isoamylol. Each sample was measured with the proposed method 30 times in repeatability conditions.

Results

Flame ionization detector response was linearly correlated with assigned concentrations at a range of 2 to 5000 mg/L of absolute alcohol (AA) with coefficients of determination (R²) more than 0.995 for all analyzed components. Repeatability (RSDr ≤ 4.5%; RSDr ≤ 2.0%), reproducibility (RSDR ≤ 5.0%; RSDR ≤ 2.0%), and trueness (relative bias ≤ 2.6%; relative bias ≤ 1.4%) were obtained for low (10-25 mg/L AA for methanol and 2-10 for other volatiles) and high (25-5000 mg/L AA for methanol and 10-5000 for other volatiles) ranges of concentrations, correspondingly.

Conclusions

The method increases the reliability of measurements and eliminates manual procedures of internal standard addition into both calibration standard solutions and spirit drinks.

Для цитирования: Charapitsa Siarhei V, Sytova Svetlana N, Korban Anton L, Sobolenko Lidia N. Single-Laboratory Validation of a Gas Chromatographic Method of Direct Determination of Volatile Compounds in Spirit Drinks: Need for an Improved Interlaboratory Study.. Journal of AOAC International. 2018. DOI: 10.5740/jaoacint.18-0258.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.