Ramsay A S, Ray-Chaudhuri N, Dayan M, Walshaw D
Аннотация
AIMS: The effect of local anaesthetics on optic nerve function can be investigated by quantifying the relative afferent pupillary defect (RAPD).
METHODS: The study compared the depth of induced RAPD following posterior sub-Tenon's, retrobulbar, and peribulbar local anaesthetics using crossed polarising filters before cataract surgery (time 1 = 5 minutes), immediately after surgery (time 2 = 42 minutes (av)), and once again on the ward (time 3 = 107 minutes (av)).
RESULTS: All patients developed a RAPD. There was no significant difference in the depth of RAPD between the groups at any one time period. The peribulbar group had a significantly steeper decay in RAPD from time 1 to time 2 (p = 0.014). This effect was reduced when the shorter operation time for this group was entered as a cofactor (p = 0.063). By time 3 the RAPDs for all groups had decayed similarly so that no differences could be detected.
CONCLUSION: All three anaesthetic methods caused a similar level of disruption to optic nerve conduction immediately following administration and at the time of day case discharge.
METHODS: The study compared the depth of induced RAPD following posterior sub-Tenon's, retrobulbar, and peribulbar local anaesthetics using crossed polarising filters before cataract surgery (time 1 = 5 minutes), immediately after surgery (time 2 = 42 minutes (av)), and once again on the ward (time 3 = 107 minutes (av)).
RESULTS: All patients developed a RAPD. There was no significant difference in the depth of RAPD between the groups at any one time period. The peribulbar group had a significantly steeper decay in RAPD from time 1 to time 2 (p = 0.014). This effect was reduced when the shorter operation time for this group was entered as a cofactor (p = 0.063). By time 3 the RAPDs for all groups had decayed similarly so that no differences could be detected.
CONCLUSION: All three anaesthetic methods caused a similar level of disruption to optic nerve conduction immediately following administration and at the time of day case discharge.