MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivaf115

Медицинская библиотека · Interdisciplinary cardiovascular and thoracic surgery · 2025

Characteristics of calcium deposition on expanded polytetrafluoroethylene membrane as a valve substitute in the pulmonary position.

Konishi Hayato, Suzuki Akiyo, Katsumata Takahiro, Fujisawa Yu, Motoyoshi Tetsuya, Nemoto Shintaro

СтатьяКлинический случайПеревод в очереди

Аннотация

An expanded polytetrafluoroethylene membrane has been widely used off-label as a substitute for a pulmonary valve leaflet. However, details regarding the calcification of the membrane in human samples have not been fully described. This report observed the precise extent and distribution of calcification in the membrane. Two samples of calcified expanded polytetrafluoroethylene membranes used as pulmonary valve substitutes were taken at replacement surgery 10 and 15 years after implantation into a valved conduit or transannular patch, respectively. In addition to general histological examination, 3D micro-computed tomography imaging and scanning electron microscopy-backscattered electron imaging were performed to reveal the precise location and extent of calcium deposition in the excised valve leaflets. Along with mineralization across the immobile membrane embedded in calcified pseudointimal tissue, calcium deposits were also detected in micro-interstices of the membrane in areas not covered by calcified fibrous tissue in both specimens. Fluorine properties and specific membrane interstices structure may cause unique calcium deposition independent of the foreign body reactions, leading to transmural calcification with thick pseudointimal embedding.

Для цитирования: Konishi Hayato, Suzuki Akiyo, Katsumata Takahiro, Fujisawa Yu, Motoyoshi Tetsuya, Nemoto Shintaro. Characteristics of calcium deposition on expanded polytetrafluoroethylene membrane as a valve substitute in the pulmonary position.. Interdisciplinary cardiovascular and thoracic surgery. 2025. DOI: 10.1093/icvts/ivaf115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.