MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/won.0000000000000748

Медицинская библиотека · Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society · 2021

Sustained Reduction of Nasal Pressure Injuries in the Neonatal Intensive Care Unit With the Use of Bubble Continuous Positive Airway Pressure: A Quality Improvement Project.

Lawrence Christie, Mohr Lynn D, Geistkemper Anne, Murphy Sara, Fleming Kellianne

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this interprofessional team-driven quality improvement project was to implement a Bubble continuous positive airway pressure (CPAP) Skincare Protocol proactively to prevent potential device-related pressure injuries.

PARTICIPANTS AND

SETTING

The setting was a level 3, 60-bed single patient room neonatal intensive care unit (NICU) located within a Midwest urban academic medical center with more than 200 healthcare providers. Prior to the beginning of this project, the NICU had been using the CPAP apparatus that had documented 6 nasal pressure injuries over a 6-month period. Because of ease of use, the NICU moved to using Bubble CPAP (BCPAP), which is known to place patients at a higher risk of nasal pressure injuries due to the way the apparatus sits inside the nares.

APPROACH: An evidence-based practice model provided the guiding framework for the development of our BCPAP Skincare Protocol. Knowing that the unit had already documented nasal pressure injuries, the interprofessional-devised protocol was developed to decrease the risk of nasal injuries with the use of BCPAP in premature infants. The protocol was disseminated via an all-healthcare provider educational program.

OUTCOMES: During the first 3 months postprotocol implementation period, one stage 2 nasal injury was noted and immediately treated and healed without incident. During the next 24-month, postimplementation period, there were zero nasal pressure injuries reported.

IMPLICATIONS FOR PRACTICE: The healthcare providers found that using an interprofessional team approach in developing and implementing an evidence-based BCPAP Skincare Protocol reduced the incidence of nasal pressure injuries associated with the use of BCPAP in the NICU.

Для цитирования: Lawrence Christie, Mohr Lynn D, Geistkemper Anne, Murphy Sara, Fleming Kellianne. Sustained Reduction of Nasal Pressure Injuries in the Neonatal Intensive Care Unit With the Use of Bubble Continuous Positive Airway Pressure: A Quality Improvement Project.. Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society. 2021. DOI: 10.1097/won.0000000000000748.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.