MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0194599820931805

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2020

Airborne Aerosol Generation During Endonasal Procedures in the Era of COVID-19: Risks and Recommendations.

Workman Alan D, Jafari Aria, Welling D Bradley, Varvares Mark A, Gray Stacey T, Holbrook Eric H, Scangas George A, Xiao Roy, Carter Bob S, Curry William T, Bleier Benjamin S

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

In the era of SARS-CoV-2, the risk of infectious airborne aerosol generation during otolaryngologic procedures has been an area of increasing concern. The objective of this investigation was to quantify airborne aerosol production under clinical and surgical conditions and examine efficacy of mask mitigation strategies.

STUDY

DESIGN

Prospective quantification of airborne aerosol generation during surgical and clinical simulation.

SETTING

Cadaver laboratory and clinical examination room.

SUBJECTS AND

METHODS

Airborne aerosol quantification with an optical particle sizer was performed in real time during cadaveric simulated endoscopic surgical conditions, including hand instrumentation, microdebrider use, high-speed drilling, and cautery. Aerosol sampling was additionally performed in simulated clinical and diagnostic settings. All clinical and surgical procedures were evaluated for propensity for significant airborne aerosol generation.

RESULTS

Hand instrumentation and microdebridement did not produce detectable airborne aerosols in the range of 1 to 10 μm. Suction drilling at 12,000 rpm, high-speed drilling (4-mm diamond or cutting burs) at 70,000 rpm, and transnasal cautery generated significant airborne aerosols (P < .001). In clinical simulations, nasal endoscopy (P < .05), speech (P < .01), and sneezing (P < .01) generated 1- to 10-μm airborne aerosols. Significant aerosol escape was seen even with utilization of a standard surgical mask (P < .05). Intact and VENT-modified (valved endoscopy of the nose and throat) N95 respirator use prevented significant airborne aerosol spread.

CONCLUSION

Transnasal drill and cautery use is associated with significant airborne particulate matter production in the range of 1 to 10 μm under surgical conditions. During simulated clinical activity, airborne aerosol generation was seen during nasal endoscopy, speech, and sneezing. Intact or VENT-modified N95 respirators mitigated airborne aerosol transmission, while standard surgical masks did not.

Для цитирования: Workman Alan D, Jafari Aria, Welling D Bradley, Varvares Mark A, Gray Stacey T, Holbrook Eric H, Scangas George A, Xiao Roy, Carter Bob S, Curry William T, Bleier Benjamin S. Airborne Aerosol Generation During Endonasal Procedures in the Era of COVID-19: Risks and Recommendations.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2020. DOI: 10.1177/0194599820931805.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.