DOI 10.1159/000113427

Медицинская библиотека · Cardiology · 2008

Atrial fibrillation following device closure of patent foramen ovale.

Burow Annika, Schwerzmann Markus, Wallmann Dieter, Tanner Hildegard, Sakata Takao, Windecker Stephan, Meier Bernhard, Delacrétaz Etienne

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Recurrent embolic events after device closure of patent foramen ovale (PFO) have been related to incomplete closure. Another cause could be atrial fibrillation (AF). The aim of this study was to determine the incidence of AF in stroke patients after PFO closure.

METHODS

Consecutive patients with device closure of a PFO after a stroke or transient ischemic attack and control patients with stroke underwent 7-day event loop recordings 3 and 6 months after PFO closure or stroke, respectively.

RESULTS

Forty patients treated by PFO device closure 96 +/- 68 days after cryptogenic ischemic stroke and 70 control patients with ischemic stroke of other etiologies (known AF excluded) were compared. AF was identified in 6 patients (15%) of the treated group and in 12 control patients (17%, p = 0.77). In multivariate analysis, the presence of an occluder device was not an independent risk factor for AF.

CONCLUSIONS

The incidence of AF is high after device closure of a PFO in stroke patients and similar to that in patients with stroke of non-PFO etiology and, hence, with no device. Further studies are required to determine the risk of thromboembolism and the optimal treatment in patients developing AF after device closure of a PFO.

Для цитирования: Burow Annika, Schwerzmann Markus, Wallmann Dieter, Tanner Hildegard, Sakata Takao, Windecker Stephan, Meier Bernhard, Delacrétaz Etienne. Atrial fibrillation following device closure of patent foramen ovale.. Cardiology. 2008. DOI: 10.1159/000113427.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.