Loop-Mediated Isothermal Amplification Assay Using Gold Nanoparticles for Detecting Treponema pallidum subspp. pallidum.

Phurijaruyangkun Saranthum, Tangjitrungrot Pongbun, Jaratsing Pornpun, Augkarawaritsawong Suphitcha, Pongparit Sawanya, Veeramano Rungnapa, Tanomnuch Kularb, Areekit Supatra, Chansiri Kosum, Santiwatanakul Somchai

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Venereal syphilis in humans is caused by Trepenoma pallidum subspp. pallidum. A study has shown that 30,302 individuals in Thailand had syphilis in 2020, with a male-to-female ratio of 1:0.8 and the highest incidence rate at ages between fifteen and twenty-four.

METHODS

This research aimed to develop a loop-mediated isothermal amplification assay using gold nanoparticles (LAMP-AuNPs). Analytical sensitivity, diagnostic specificity, accuracy, and predictive values for each technique are provided.

RESULTS

The diagnosis sensitivities of polymerase chain reaction using agarose gel electrophoresis (PCR-AGE), loop-mediated isothermal amplification assay using agarose gel electrophoresis (LAMP-AGE), and LAMP-AuNPs were 116 ng/µL, 11.6 ng/µL, and 11.6 ng/µL, respectively. We evaluated the analytical specificity using PCR and a LAMP-based assay, and there was no cross-reactivity to Leptospira interrogans, Staphylococcus aureus, Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, human immunodeficiency virus (HIV), and healthy humans. After analyzing 400 serum samples of patients suspected of syphilis, the LAMP-AGE and LAMP-AuNPs assays displayed 100% diagnostic sensitivity scores, 91% diagnostic specificity scores, 95.5% accuracy rates, 100% positive predictive values (PPVs), and 91% negative predictive values (NPVs), the positive likelihood ratio (LR+) was 11.11, while the negative likelihood ratio (LR-) was 0. Conversely, for PCR assays displayed 100% diagnostic sensitivity scores, 94.5% diagnostic specificity scores, 97.25% accuracy rates, 100% PPVs, and 94.5% NPVs, LR+ was 18.18, and LR- was 0.

CONCLUSIONS

The LAMP-AuNPs technique demonstrates rapidity, affordability, and convenience, rendering it well-suited for point-of-care applications in the diagnosis, prevention, and management of pathogenic infections.

Для цитирования: Phurijaruyangkun Saranthum, Tangjitrungrot Pongbun, Jaratsing Pornpun, Augkarawaritsawong Suphitcha, Pongparit Sawanya, Veeramano Rungnapa, Tanomnuch Kularb, Areekit Supatra, Chansiri Kosum, Santiwatanakul Somchai. Loop-Mediated Isothermal Amplification Assay Using Gold Nanoparticles for Detecting Treponema pallidum subspp. pallidum.. Diagnostics (Basel, Switzerland). 2024. DOI: 10.3390/diagnostics14202323.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.