Quality control evaluation of nutraceutical products from Ginkgo biloba using liquid chromatography coupled to high resolution mass spectrometry.

López-Gutiérrez Noelia, Romero-González Roberto, Vidal José Luis Martínez, Frenich Antonia Garrido

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Analysis of 11 commercial nutraceutical products obtained from ginkgo has been performed using ultra-high performance liquid chromatography coupled to single-stage Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-MS). The main phytochemicals present in these samples were detected and quantified, utilizing a database containing 65 compounds. Phytochemicals were extracted using a mixture of an aqueous solution of methanol:water (80:20, v/v) in two sequential solid-liquid extractions. Adequate validation parameters were obtained. The validated compounds exhibited suitable linearity with determination coefficients (R(2)) higher than 0.99, and intra and inter-day precision were lower than 17 and 22%, respectively. Limits of detection (LODs) and quantification (LOQs) were calculated, ranging from 2 to 10 μg L(-1), except for myricetin (LOD, 150 μg L(-1) and LOQ, 300 μg L(-1)). Results indicate that the amount of terpenoids greatly varies among samples, ranging from 1133 (C7) to 12706 mg kg(-1) (C11). This emphasizes the importance of improve quality control in ginkgo-based products. Moreover, retrospective analysis allowed the detection of some undesirable substances as ginkgolic acid in the samples evaluated.

Для цитирования: López-Gutiérrez Noelia, Romero-González Roberto, Vidal José Luis Martínez, Frenich Antonia Garrido. Quality control evaluation of nutraceutical products from Ginkgo biloba using liquid chromatography coupled to high resolution mass spectrometry.. Journal of pharmaceutical and biomedical analysis. 2016. DOI: 10.1016/j.jpba.2016.01.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.