Wu Yu-Cheng, Wang Mei-Xiang, Chen Ge-Cai, Ruan Zhong-Bao, Zhang Qing-Qing
Аннотация
BACKGROUND: In patients who suffer from both atrial fibrillation (AF) and atrial septal defect (ASD), cryoballoon pulmonary vein isolation (PVI), sequential left atrial appendage (LAA) occlusion and ASD closure could be a strategy for effective prevention of stroke and right heart failure.
CASE SUMMARY: A 65-year-old man was admitted to our institution due to recurrent episodes of palpitations and shortness of breath for 2 years, which had been worsening over the last 48 h. He had a history of AF, ASD, coronary heart disease with stent implantation and diabetes. Physical and laboratory examinations showed no abnormalities. The score of CHA2DS2VASc was 3, and HAS-BLED was 1. Echocardiography revealed a 25-mm secundum ASD. Pulmonary vein (PV) and LAA anatomy were assessed by cardiac computed tomography. PV mapping with 10-pole Lasso catheter was performed following ablation of all four PVs with complete PVI. Following the cryoballoon PVI, the patient underwent LAA occlusion under transesophageal echocardiographic monitoring. Lastly, a 34-mm JIYI ASD occlude device was implanted. A follow-up transesophageal echocardiography at 3 mo showed proper position of both devices and neither thrombi nor leakage was found.
CONCLUSION: Sequential cryoballoon PVI and LAA occlusion prior to ASD closure can be performed safely in AF patients with ASD.
CASE SUMMARY: A 65-year-old man was admitted to our institution due to recurrent episodes of palpitations and shortness of breath for 2 years, which had been worsening over the last 48 h. He had a history of AF, ASD, coronary heart disease with stent implantation and diabetes. Physical and laboratory examinations showed no abnormalities. The score of CHA2DS2VASc was 3, and HAS-BLED was 1. Echocardiography revealed a 25-mm secundum ASD. Pulmonary vein (PV) and LAA anatomy were assessed by cardiac computed tomography. PV mapping with 10-pole Lasso catheter was performed following ablation of all four PVs with complete PVI. Following the cryoballoon PVI, the patient underwent LAA occlusion under transesophageal echocardiographic monitoring. Lastly, a 34-mm JIYI ASD occlude device was implanted. A follow-up transesophageal echocardiography at 3 mo showed proper position of both devices and neither thrombi nor leakage was found.