m+Medelevator.RU
← Поиск публикаций
Frontiers in medicine · 2026

Robust colonoscopy polyp segmentation using dynamic-Nu T-Loss with multi-scale and uncertainty-aware adaptation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Norouziazad Alireza, Fardshad Mahan Najafpour Ghazvini, Esmaeildoost Fatemeh, Fardshad Mehrdad Najafpour Ghazvini, Salahandish Razieh

Аннотация

Accurate segmentation of polyps in colonoscopy images is essential for early colorectal cancer detection; however, it remains a challenging task due to reflections, occlusions, motion artifacts, inter- and intra-polyp appearance variability, and the presence of noisy or inconsistent ground-truth annotations. In this work, we introduce dynamic-Nu T-Loss (DNA-TLoss), a robust, adaptive loss function based on the heavy-tailed Student's 𝑡-distribution that incorporates three novel extensions: (1) a per-image learnable degrees-of-freedom parameter ν, predicted by a lightweight NuPredictor network to dynamically adjust robustness to outliers; (2) per-pixel precision weights λ for spatially adaptive error sensitivity; and (3) a multi-scale aggregation scheme that computes and combines loss at multiple spatial resolutions to capture both coarse and fine details. Integrated into a U-Net with a ResNet-34 encoder, DNA-TLoss was evaluated on five public benchmarks: CVC-300, CVC-ClinicDB, ETIS-LaribPolypDB, Kvasir, and CVC-ColonDB. Our method achieves the lowest Hausdorff distance across all datasets, with an average reduction of 14.6% compared to T-Loss; notably, on CVC-300, it yields a significant decrease of 45.96%. It also obtains the lowest false discovery rate on all five datasets, improving over T-Loss by up to 38.7% on CVC-300 and 24.5% on Kvasir. Furthermore, DNA-TLoss provided best-in-class calibration, achieving expected calibration error as low as 0.44% on CVC-300 and outperforming all other baselines on four out of five datasets. These results highlight the promise of joint global and local uncertainty adaptation, coupled with multi-scale optimization, for advancing trustworthy, real-time computer-aided polyp detection in colonoscopy.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты