MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1243/0954411971534395

Медицинская библиотека · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 1997

Intraoperative guidance in maxillofacial and craniofacial surgery.

Hassfeld S, Muehling J, Wirtz C R, Knauth M, Lutze T, Schulz H J

Клинический случайСтатьяПеревод в очереди

Аннотация

The authors' experiences with intraoperative computer assisted guidance in interventions in oromaxillofacial and craniofacial surgery are reported. The guidance system SPOCS (Surgical Planning and Orientation Computer Systems, Aesculap, Germany) consists of an infrared light emitting system of diodes and camera, an imaging workstation and assorted freehand instruments. The software is an updated version of the well-known Viewing Wand software (ISG Technologies, Canada). In tests on phantoms, the system proved a mean accuracy of less than 1.5 mm. Within the last 15 clinical tests, the system has achieved an accuracy better than 3 mm which, at the moment, the authors estimate to be sufficient to proceed with its clinical evaluation. Using bone screws to register the patient's position, an accuracy in the range of less than 2 mm in relation to bony reference points has been achieved. By visualizing the tip of the instrument in real time, this technique allows surgical interventions, even in anatomically complicated situations, without endangering vital neighbouring structures. The 'offset' function of the software, by which the surgeon can elongate the tip of the instrument virtually, allows the surgeon to analyse structures before they are penetrated by the instrument as in a 'look ahead' operation. The authors expect computer assisted simulation and guidance systems to improve surgical quality and reduce the risks associated with surgical interventions.

Для цитирования: Hassfeld S, Muehling J, Wirtz C R, Knauth M, Lutze T, Schulz H J. Intraoperative guidance in maxillofacial and craniofacial surgery.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 1997. DOI: 10.1243/0954411971534395.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.