m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular development and disease · 2026

Pulsed Field Ablation Versus High-Power Short-Duration Ablation for Atrial Fibrillation-A Meta-Analysis of Reconstructed Time-to-Event Data.

СтатьяОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bregion Pedro B, Passos Felipe S, Schena Stefano, Fazzini Luca, Kirov Hristo, Rossi Camilla S, Doenst Torsten, Di Franco Antonino, Caldonazo Tulio

Аннотация

BACKGROUND: Pulsed field ablation (PFA) has shown promising results for atrial fibrillation (AF), with efficacy comparable to established ablation techniques. High-power short-duration (HPSD) ablation has also emerged as a potential alternative. However, the relative superiority between these approaches remains uncertain. We performed a systematic review and meta-analysis to address this gap.

METHODS: Three databases were searched. The primary outcome was freedom from AF recurrence. Secondary outcomes included tamponade and other complications, procedure and fluoroscopy durations. Time-to-event data were reconstructed, and a random-effects model was employed. Given variability in post-ablation blanking periods across studies, landmark analyses were performed using a 3-month cut-off to account for the potential under-detection of early recurrence events.

RESULTS: Eight studies (1369 patients [PFA: 642; HPSD: 727]) were included. PFA was associated with greater freedom from AF recurrence (HR 0.751; 95% CI 0.57 to 0.99; p = 0.044). Landmark analyses showed no difference in the 0-3 month period; a significant benefit of PFA was observed thereafter (HR 0.72; 95% CI 0.54 to 0.98; p = 0.033). There were no significant differences between groups in the incidence of tamponade (p = 0.73) or overall complications (p = 0.99). PFA was associated with shorter procedure duration (MD 37.05; 95% CI 27.69 to 46.41; p < 0.01), whereas fluoroscopy duration was significantly shorter in the HPSD group (MD -9.04; 95% CI -11.71 to -6.37; p < 0.001).

CONCLUSION: PFA was associated with a lower risk of AF recurrence compared to HPSD, particularly beyond the late post-ablation period, with similar rates of complications. Although PFA was associated with shorter procedure duration, HPSD demonstrated reduced fluoroscopy time.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты