OBJECTIVES

This study aimed to evaluate which of four established norms should be used for sonographic assessment of fetal femur length (FL).

STUDY

DESIGN

Cross-sectional study using pooled data from four maternal-fetal medicine practices. Inclusion criteria were singleton fetus, gestational age (GA) 220/7 to 396/7 weeks, biometry measured, and fetal cardiac activity present. Four norms of FL were studied: Hadlock et al, the INTERGROWTH-21st Project (IG-21st), the World Health Organization Fetal Growth Curves (WHO), and the National Institutes of Child Health and Human Development Fetal Growth Studies, unified standard (NICHD-U). The fit of our FL measurements to each norm was assessed by these criteria: mean z-score close to 0, standard deviation (SD) of z close to 1, Kolmogorov-Smirnov D-statistic close to zero, Youden J-statistic close to 1, approximately 5% of exams <5th percentile, and approximately 5% of exams >95th percentile.

RESULTS

In 26,177 ultrasound exams, our FL measurements had the best fit to the WHO standard (mean z-score 0.15, SD of z 1.02, D-statistic <0.01, J-statistic 0.95, 3.4% of exams <5th percentile, 7.0% of exams >95th percentile). The mean of the IG-21st standard was smaller than the other norms and smaller than our measurements, resulting in underdiagnosis of short FL. The mean of the Hadlock reference was larger than the other norms and larger than our measurements, resulting in overdiagnosis of short FL. The SD of the NICHD-U standard was larger than the other norms and larger than our observations, resulting in underdiagnosis of both short and long FL. Restricting the analysis to a subgroup of 7,144 low-risk patients without risk factors for large- or small-for- GA produced similar results.

CONCLUSION

Of the norms studied, the WHO standard is likely best for diagnosis of abnormal FL.

KEY POINTS: · There are >30 norms for fetal FL.. · It is unknown which norm should be used.. · Our data fit the World Health Organization standard better than the other norms..

Для цитирования: Combs C Andrew, Del Rosario Amber, Ashimi Balogun Olaide, Bowman Zachary S, Amara Sushma. Selection of Standards for Sonographic Fetal Femur Length by Use of z-scores.. American journal of perinatology. 2023. DOI: 10.1055/a-2196-6835.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.