PURPOSE: The treatment of high-energy tibial condylar fractures which are associated with severe soft tissue injuries remains contentious and challenging. In this study, we assessed the results of Joshi's external stabilization system (JESS) by using the principle of ligamentotaxis and percutaneous screw fixation for managing high-energy tibial condylar fractures associated with severe soft tissue injuries.

METHODS

Between June 2008 and June 2010, 25 consecutive patients who were 17e71 years (mean, 39.7), underwent the JESS fixation for high-energy tibial condylar fractures associated with severe soft tissue injuries. Out of 25 patients, 2 were lost during follow-up and in 1 case early removal of frame was done, leaving 22 cases for final follow-up. Among them, 11 had poor skin condition with abrasions and blisters and 2 were open injuries (Gustilo-Anderson grade I&II). The injury mechanisms were motor vehicle accidents (n=19), fall from a height (n=2) and assault (n=1). The fractures were classified according to Schatzker classification system.

RESULTS

There were 7 type-V, 14 type-VI and 1 type-lV Schatzker's tibial plateau fractures. The average interval between the injury and surgery was 6.8 days (range 2-13). The average hospital stay was 13 days (range, 7-22). The average interval between the surgery and full weight bearing was 13.6 weeks (range 11-20). The average range of knee flexion was 121°(range 105°-135°). The normal extension of the knee was observed in 20 patients, and an extensor lag of 5°-8° was noted in 2 patients. The complications included superficial pin tract infections (n=4) with no knee stiffness.

CONCLUSION

JESS with lag screw fixation combines the benefit of traction, external fixation, and limited internal fixation, at the same time as allowing the ease of access to the soft tissue for wound checks, pin care, dressing changes, measurement of compartment pressure, and the monitoring of the neurovascular status. In a nutshell, JESS along with screw fixation offers a promising alternative treatment for high- energy tibial condylar fractures associated with severe soft tissue injuries.

Для цитирования: Gupta Ashish-Kumar, Sapra Rahul, Kumar Rakesh, Gupta Som-Prakash, Kaushik Devwart, Gaba Sahil, Bansal Mahesh Chand, Dayma Ratan Lal. Role of Joshi's external stabilization system with percutaneous screw fixation in high-energy tibial condylar fractures associated with severe soft tissue injuries.. Chinese journal of traumatology = Zhonghua chuang shang za zhi. 2015. DOI: 10.1016/j.cjtee.2015.11.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.