MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apradiso.2026.112876

Медицинская библиотека · Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026

Experimental validation of the scintiPulses shot-noise model for coincidence resolving-time dependencies in liquid scintillation counting.

Coulon Romain

СтатьяПеревод в очереди

Аннотация

In Liquid Scintillation Counting (LSC), the accurate standardization of pure beta and low-energy electron emitters relies heavily on coincidence detection architectures, where the coincidence resolving time is a highly sensitive parameter. Signal quantization and delayed fluorescence cause a delay in the initial detected charge, leading to significant event loss if the coincidence window is not appropriately set. To elucidate the physical mechanisms driving this resolving-time dependence, this study employs a comprehensive Monte Carlo framework utilizing the open-source Python packages TDCRPy and scintiPulses to emulate the entire detection chain. Experimental measurements of 3H, 55Fe, and 14C utilizing a Triple-to-Double Coincidence Ratio (TDCR) system were compared against single- and double-exponential scintillation decay models. The results demonstrate that while a single-exponential model accurately captures prompt stochastic jittering for short resolving times (under 20 ns), it significantly underestimates detection efficiencies at larger windows. Introducing a delayed fluorescence component successfully corrects this drift, achieving agreement between the model and experimental data within ±1% for double coincidences across all tested resolving times. These findings validate the shot-noise model implemented in scintiPulses to emulate the scintillation signal and perfectly corrects that delayed fluorescence, driven by triplet-triplet annihilation, is the primary physical mechanism responsible for resolving-time-dependent efficiency variations in LSC systems.

Для цитирования: Coulon Romain. Experimental validation of the scintiPulses shot-noise model for coincidence resolving-time dependencies in liquid scintillation counting.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2026. DOI: 10.1016/j.apradiso.2026.112876.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.