m+Medelevator.RU
← Поиск публикаций
Clinical implant dentistry and related research · 2025

Peri-Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Borie Manon, Bosshardt Dieter, Liegeois Lemmy, Lecloux Geoffrey, Jostein Haugen Håvard, Van Hede Dorien, Lambert France

Аннотация

BACKGROUND: The peri-implant soft tissue integration is critical to maintain peri-implant health and the long-term success of dental implant rehabilitations.

AIM: This comparative histomorphometry study aims to characterize the peri-implant soft tissues (PIST) around experimental abutments made of titanium (Ti), dental resin (Re), and polyetheretherketone (PEEK).

METHODS: Thirty bone-level implants were placed, each receiving an experimental transmucosal healing abutment made of one of the three materials. After an 8-week healing period, the abutments and surrounding tissues were harvested and prepared for histological and histomorphometric analyses. Dimensions of sulcus depth, epithelial and connective tissue adhesion were measured. In addition, the abutment surface characteristics, levels of inflammation, plaque accumulation, and peri-implant bone level changes were evaluated.

RESULTS: The dimensions of the different components of the PIST were comparable across the three experimental groups. The mean overall dimensions of the PIST were 2.68 ± 0.51 mm for Ti, 2.66 ± 0.47 mm for Re, and 2.32 ± 0.55 mm for PEEK. Mean sulcus depth was 0.71 ± 0.69 mm for Ti, 0.74 ± 0.50 mm for Re, and 0.68 ± 0.63 mm for PEEK. Mean junctional epithelium was 1.82 ± 0.67 mm for Ti, 1.56 ± 0.47 mm for Re, and 1.53 ± 0.40 mm for PEEK. Mean harvested connective tissue (until abutment platform) was 0.30 ± 0.29 mm for Ti, 0.36 ± 0.38 mm for Re, and 0.09 ± 0.10 mm for PEEK. However, the resin group exhibited significantly more supramucosal biofilm adhesion (p = 0.026).

CONCLUSION: The PIST around abutments made of PEEK, resin, or titanium tend to develop in a similar pattern. However, longer observation periods are required to evaluate the long-term effects.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты