MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.70083

Медицинская библиотека · Clinical implant dentistry and related research · 2025

Peri-Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study.

Borie Manon, Bosshardt Dieter, Liegeois Lemmy, Lecloux Geoffrey, Jostein Haugen Håvard, Van Hede Dorien, Lambert France

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The peri-implant soft tissue integration is critical to maintain peri-implant health and the long-term success of dental implant rehabilitations.

AIM: This comparative histomorphometry study aims to characterize the peri-implant soft tissues (PIST) around experimental abutments made of titanium (Ti), dental resin (Re), and polyetheretherketone (PEEK).

METHODS

Thirty bone-level implants were placed, each receiving an experimental transmucosal healing abutment made of one of the three materials. After an 8-week healing period, the abutments and surrounding tissues were harvested and prepared for histological and histomorphometric analyses. Dimensions of sulcus depth, epithelial and connective tissue adhesion were measured. In addition, the abutment surface characteristics, levels of inflammation, plaque accumulation, and peri-implant bone level changes were evaluated.

RESULTS

The dimensions of the different components of the PIST were comparable across the three experimental groups. The mean overall dimensions of the PIST were 2.68 ± 0.51 mm for Ti, 2.66 ± 0.47 mm for Re, and 2.32 ± 0.55 mm for PEEK. Mean sulcus depth was 0.71 ± 0.69 mm for Ti, 0.74 ± 0.50 mm for Re, and 0.68 ± 0.63 mm for PEEK. Mean junctional epithelium was 1.82 ± 0.67 mm for Ti, 1.56 ± 0.47 mm for Re, and 1.53 ± 0.40 mm for PEEK. Mean harvested connective tissue (until abutment platform) was 0.30 ± 0.29 mm for Ti, 0.36 ± 0.38 mm for Re, and 0.09 ± 0.10 mm for PEEK. However, the resin group exhibited significantly more supramucosal biofilm adhesion (p = 0.026).

CONCLUSION

The PIST around abutments made of PEEK, resin, or titanium tend to develop in a similar pattern. However, longer observation periods are required to evaluate the long-term effects.

Для цитирования: Borie Manon, Bosshardt Dieter, Liegeois Lemmy, Lecloux Geoffrey, Jostein Haugen Håvard, Van Hede Dorien, Lambert France. Peri-Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study.. Clinical implant dentistry and related research. 2025. DOI: 10.1111/cid.70083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.