Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cakal Berkay A, Pirkovets Kateryna, Ottens Vera A, Zuur Lotte, Sinaasappel Michiel, Gandaglia Giorgio, Briganti Alberto, van der Poel Henk G, van Leeuwen Pim J, van Leeuwen Fijs W B
Аннотация
Radioguided surgery (RGS) using prostate-specific membrane antigen (PSMA)-targeted tracers is frequently hampered by relatively low intraoperative signal intensities. This limits intraoperative target discrimination when feedback relies solely on probe counts per second. We evaluated whether real-time signal-to-background ratio (SBR) feedback, integrated into the robotic console via a graphical user interface (GUI), improves surgical perception, decisiveness, and scanning efficiency during drop-in PSMA-radioguided procedures. Methods: We retrospectively analyzed 10 patients from the TRACE-II trial undergoing salvage RGS with 99mTc-PSMA imaging and surgery. Five procedures were performed with standard counts per second feedback (control group), and 5 were performed with additional live SBR feedback (experiment group). The GUI enabled intraoperative background sampling and displayed real-time SBRs via a traffic light-style color-coded gauge. Probe trajectories were reconstructed using video-based tracking with green polyetheretherketone marker rings, and scanning performance was quantified by total scan duration and target scan duration. Statistical comparisons were made using Mann-Whitney U and Spearman correlation analyses. Results: Fourteen PSMA-avid lesions were resected, all of which were confirmed by pathology as cancerous. Cases with real-time SBR feedback showed more focused probe trajectories and reduced procedure times. The median total scan duration decreased from 455 to 237 s (P = 0.11), and the median target scan duration decreased from 299 to 212 s (P = 0.15). Although not statistically significant in this pilot study, scan durations strongly correlated with in vivo counts (Spearman ρ = -0.74, P = 0.01). After normalization for maximum in vivo counts, median target scan duration decreased from 21.1 to 5.3 seconds per counts per second (s/cps) (P = 0.08). Conclusion: Streaming real-time SBR feedback into the robotic console improved surgical decisiveness and perception of PSMA-avid lesions and facilitated more efficient probe handling. By digitizing intraoperative contrast information, the drop-in γ-probe provided actionable feedback that reduced cognitive load and enhanced target discrimination. These findings support future multicenter studies to establish standardized SBR-based performance metrics in RGS.