Медицинская библиотека · Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026

Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery.

Cakal Berkay A, Pirkovets Kateryna, Ottens Vera A, Zuur Lotte, Sinaasappel Michiel, Gandaglia Giorgio, Briganti Alberto, van der Poel Henk G, van Leeuwen Pim J, van Leeuwen Fijs W B

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Radioguided surgery (RGS) using prostate-specific membrane antigen (PSMA)-targeted tracers is frequently hampered by relatively low intraoperative signal intensities. This limits intraoperative target discrimination when feedback relies solely on probe counts per second. We evaluated whether real-time signal-to-background ratio (SBR) feedback, integrated into the robotic console via a graphical user interface (GUI), improves surgical perception, decisiveness, and scanning efficiency during drop-in PSMA-radioguided procedures.

Methods

We retrospectively analyzed 10 patients from the TRACE-II trial undergoing salvage RGS with 99mTc-PSMA imaging and surgery. Five procedures were performed with standard counts per second feedback (control group), and 5 were performed with additional live SBR feedback (experiment group). The GUI enabled intraoperative background sampling and displayed real-time SBRs via a traffic light-style color-coded gauge. Probe trajectories were reconstructed using video-based tracking with green polyetheretherketone marker rings, and scanning performance was quantified by total scan duration and target scan duration. Statistical comparisons were made using Mann-Whitney U and Spearman correlation analyses.

Results

Fourteen PSMA-avid lesions were resected, all of which were confirmed by pathology as cancerous. Cases with real-time SBR feedback showed more focused probe trajectories and reduced procedure times. The median total scan duration decreased from 455 to 237 s (P = 0.11), and the median target scan duration decreased from 299 to 212 s (P = 0.15). Although not statistically significant in this pilot study, scan durations strongly correlated with in vivo counts (Spearman ρ = -0.74, P = 0.01). After normalization for maximum in vivo counts, median target scan duration decreased from 21.1 to 5.3 seconds per counts per second (s/cps) (P = 0.08).

Conclusion

Streaming real-time SBR feedback into the robotic console improved surgical decisiveness and perception of PSMA-avid lesions and facilitated more efficient probe handling. By digitizing intraoperative contrast information, the drop-in γ-probe provided actionable feedback that reduced cognitive load and enhanced target discrimination. These findings support future multicenter studies to establish standardized SBR-based performance metrics in RGS.

Для цитирования: Cakal Berkay A, Pirkovets Kateryna, Ottens Vera A, Zuur Lotte, Sinaasappel Michiel, Gandaglia Giorgio, Briganti Alberto, van der Poel Henk G, van Leeuwen Pim J, van Leeuwen Fijs W B. Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery.. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2026. DOI: 10.2967/jnumed.125.271693.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.