MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10286-017-0454-2

Медицинская библиотека · Clinical autonomic research : official journal of the Clinical Autonomic Research Society · 2017

Transcranial Doppler in autonomic testing: standards and clinical applications.

Norcliffe-Kaufmann Lucy, Galindo-Mendez Brahyan, Garcia-Guarniz Ana-Lucia, Villarreal-Vitorica Estibaliz, Novak Vera

СтатьяПоддержка NIH: внешняя программаОбзорПеревод в очереди

Аннотация

When cerebral blood flow falls below a critical limit, syncope occurs and, if prolonged, ischemia leads to neuronal death. The cerebral circulation has its own complex finely tuned autoregulatory mechanisms to ensure blood supply to the brain can meet the high metabolic demands of the underlying neuronal tissue. This involves the interplay between myogenic and metabolic mechanisms, input from noradrenergic and cholinergic neurons, and the release of vasoactive substrates, including adenosine from astrocytes and nitric oxide from the endothelium. Transcranial Doppler (TCD) is a non-invasive technique that provides real-time measurements of cerebral blood flow velocity. TCD can be very useful in the work-up of a patient with recurrent syncope. Cerebral autoregulatory mechanisms help defend the brain against hypoperfusion when perfusion pressure falls on standing. Syncope occurs when hypotension is severe, and susceptibility increases with hyperventilation, hypocapnia, and cerebral vasoconstriction. Here we review clinical standards for the acquisition and analysis of TCD signals in the autonomic laboratory and the multiple methods available to assess cerebral autoregulation. We also describe the control of cerebral blood flow in autonomic disorders and functional syndromes.

Для цитирования: Norcliffe-Kaufmann Lucy, Galindo-Mendez Brahyan, Garcia-Guarniz Ana-Lucia, Villarreal-Vitorica Estibaliz, Novak Vera. Transcranial Doppler in autonomic testing: standards and clinical applications.. Clinical autonomic research : official journal of the Clinical Autonomic Research Society. 2017. DOI: 10.1007/s10286-017-0454-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.