Face mask versus nasal prong or nasopharyngeal tube for neonatal resuscitation in the delivery room: a systematic review and meta-analysis.

СтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mangat Avneet, Bruckner Marlies, Schmölzer Georg M

Аннотация

IMPORTANCE: The current neonatal resuscitation guidelines recommend positive pressure ventilation via face mask or nasal prongs at birth. Using a nasal interface may have the potential to improve outcomes for newborn infants.

OBJECTIVE: To determine whether nasal prong/nasopharyngeal tube versus face mask during positive pressure ventilation of infants born <37 weeks' gestation in the delivery room reduces in-hospital mortality and morbidity.

DATA SOURCES: MEDLINE (through PubMed), Google Scholar and EMBASE, Clinical Trials.gov and the Cochrane Central Register of Controlled Trials through August 2019.

STUDY SELECTION: Randomised controlled trials comparing nasal prong/nasopharyngeal tube versus face mask during positive pressure ventilation of infants born <37 weeks' gestation in the delivery room.

DATA ANALYSIS: Risk of bias was assessed using the Covidence Collaboration Tool, results were pooled into a meta-analysis using a random effects model.

MAIN OUTCOME: In-hospital mortality.

RESULTS: Five RCTs enrolling 873 infants were combined into a meta-analysis. There was no statistical difference in in-hospital mortality (risk ratio (RR 0.98, 95% CI 0.63 to 1.52, p=0.92, I2=11%), rate of chest compressions in the delivery room (RR 0.37, 95% CI 0.10 to 1.33, p=0.13, I2=28%), rate of intraventricular haemorrhage (RR 1.54, 95% CI 0.88 to 2.70, p=0.13, I2=0%) or delivery room intubations in infants ventilated with a nasal prong/tube (RR 0.63, 95% CI 0.39,1.02, p=0.06, I2=52%).

CONCLUSION: In infants born <37 weeks' gestation, in-hospital mortality and morbidity were similar following positive pressure ventilation during initial stabilisation with a nasal prong/tube or a face mask.