MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5435/jaaos-d-18-00393

Медицинская библиотека · The Journal of the American Academy of Orthopaedic Surgeons · 2019

Synthetic Graft Compared With Allograft Reconstruction for Extensor Mechanism Disruption in Total Knee Arthroplasty: A Multicenter Cohort Study.

Wood Thomas J, Leighton Jennifer, Backstein David J, Marsh Jacquelyn D, Howard James L, McCalden Richard W, MacDonald Steven J, Lanting Brent A

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Extensor mechanism disruption after total knee arthroplasty is a serious complication leading to notable patient morbidity. The purpose of this study is to compare the outcomes of extensor mechanism allograft with synthetic graft reconstruction.

METHODS

We retrospectively identified all patients who underwent extensor mechanism reconstruction using either allograft or synthetic graft from two high-volume academic arthroplasty institutions between 2006 and 2017. We collected extensor lag, need for ambulatory aids, and patient-reported outcome measures, as well as the incidence of postoperative complications and revision surgeries. We evaluated cost differences, considering both material cost and the need for revision surgery.

RESULTS

We identified 27 cases. A significantly greater postoperative extensor lag was found in the allograft group (P = 0.05). Graft failure after synthetic reconstruction was zero, with an overall revision surgery rate of 15%. Graft failure was 21%, and the revision surgery rate was 43% after allograft reconstruction. The allograft cost was significantly higher compared with the synthetic graft cost (P = 0.001). The mean total cost was 4,733.08 CAD for the synthetic group and 24,050.40 CAD for the allograft group (P = 0.17).

DISCUSSION: Synthetic reconstruction for extensor mechanism disruption shows benefit in postoperative extensor lag, graft failure, revision surgery, and cost when compared with allograft.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Wood Thomas J, Leighton Jennifer, Backstein David J, Marsh Jacquelyn D, Howard James L, McCalden Richard W, MacDonald Steven J, Lanting Brent A. Synthetic Graft Compared With Allograft Reconstruction for Extensor Mechanism Disruption in Total Knee Arthroplasty: A Multicenter Cohort Study.. The Journal of the American Academy of Orthopaedic Surgeons. 2019. DOI: 10.5435/jaaos-d-18-00393.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.