m+Medelevator.RU
← Поиск публикаций
Journal of breath research · 2025

Comparison of the suitability of different sampling techniques for exhaled volatile organic compounds in dairy cows.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Eichinger Julia, Tintrop Lucie K, Siegenthaler Raphael, Reiche Anna-Maria, Dohme-Meier Frigga, Fuchsmann Pascal

Аннотация

Currently, there are no standardized procedures for sampling exhaled volatile organic compounds (VOCs) from dairy cows. Therefore, this study aimed to compare exhaled VOCs captured on solid-phase extraction (SPE) cartridges using five variants of three breath collection devices (face mask and GreenFeed system [C-Lock, South Dakota, US] collecting unfiltered [GreenFeedU] and filtered [GreenFeedF] air). The variants were: a tight-fitting face mask (MaskN), the MaskNwith the openings sealed using activated carbon filters (MaskF), the MaskNcovered with an over-mask ventilated with synthetic air for cow breathing (MaskV), the GreenFeedU, and the GreenFeedF. The variants were compared in two experiments (trial registration number (2023-30-FR) regarding possible VOC carryover over the samples (experiment 1) and their suitability for sampling exhaled VOC from cows (experiment 2). In both experiments, the SPE cartridges were connected to capture VOCs from collected air before GC-MS-based analysis. In experiment 1, our data showed evidence for VOC deposits and potential VOC carryover, particularly for GreenFeedU(16.3%). In exhaled breath samples from experiment 2, we detected 1217 ± 197 peaks. After subtracting the background air peaks, the exhaled VOCs consisted mostly of esters (20.9%), ketones (13.2%), and alkanes (13.0%). MaskVdetected the highest number of aldehydes, ketones, alcohols, alkanes, and alkenes, and GreenFeedUthe highest number of esters. The highest relative concentrations of most individual exhaled VOC were detected using MaskV. The tested variants, except MaskFdue to low acceptance of the animals, seemed suitable for exhaled VOC sampling, with MaskVseemed to be most suitable due to the detection of the highest VOC number and the lowest VOC carryover.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты