m+Medelevator.RU
← Поиск публикаций
Open heart · 2024

Pulsed-field ablation of atrial fibrillation with a pentaspline catheter across National Health Service England centres.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mills Mark T, Trivedi Saket, Lovell Matthew J, Murgatroyd Francis, Calvert Peter, Luther Vishal, Gupta Dhiraj, Martin Claire, Zeriouh Sarah, Mellor Greg, Balasubramaniam Richard, Sopher Mark, Boullin Julian, Arujuna Aruna, Chalil Shajil, Gall Scott, Chen Zhong, Saba Magdi, Buckley Una, Somani Riyaz, Chin Shui Hao, Jones David, Kaba Riyaz A, O'Neill Mark, Wong Tom, Todd Derick M

Аннотация

INTRODUCTION: Pulsed-field ablation (PFA) is a novel modality for pulmonary vein isolation in patients with atrial fibrillation (AF). We describe the initial uptake and experience of PFA using a pentaspline catheter across selected National Health Service England (NHSE) centres.

METHODS: Data collected by NHSE Specialised Services Development Programme regarding AF ablation procedures using a single-shot, pentaspline, multielectrode PFA catheter (FARAWAVE, Boston Scientific) between June 2022 and August 2024 were aggregated and analysed to examine procedural metrics, acute efficacy and safety outcomes over 3-month follow-up.

RESULTS: 1034 procedures were submitted. The patients were 32.1% female, mean age 63.8±10.7 years, 53.1% paroxysmal AF and 89.7% first-time AF ablation. Procedures were performed by 48 consultant operators at nine NHSE centres, with a mean of 115 procedures per centre (range 25-264). 93.7% of procedures were performed under general anaesthesia. Median skin-to-skin procedure time was 74 min (IQR 55-96 min) and fluoroscopy time 20 min (IQR 15-27 min). Electroanatomical mapping was used in 15.3%. In first-time ablation cases, acute isolation of all pulmonary veins was achieved in 99.5% of patients. Left atrial (LA) posterior wall ablation using the PFA catheter was performed in 11.0% of cases; additional LA radiofrequency ablation was performed in 0.6%. The major and minor acute procedural complication rates were, respectively, 1.3% and 3.1%, with no reports of periprocedural death or atrio-oesophageal fistula. 63.8% of patients were discharged on the day of procedure. Follow-up data were available for 870 procedures (84.1%). In the 3 months following ablation, hospitalisation for arrhythmia occurred in 3.2%, with 0.9% rehospitalised for procedural-related complications.

CONCLUSION: In this real-world, nationwide registry of a pentaspline PFA catheter, efficacy, safety and efficiency outcomes were comparable to those from previous PFA studies in patients with AF.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты