m+Medelevator.RU
← Поиск публикаций
Physiological research · 2013

The effect of aortic coarctation surgical repair on QTc and JTc dispersion in severe aortic coarctation newborns: a short-term follow-up study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nigro G, Russo V, Rago A, Papa A A, Cioppa N D, Scarpati C, Palladino T, Corcione A, Sarubbi B, Caianiello G, Russo M G

Аннотация

Sudden death is a possible occurrence for newborns younger than 1 year with severe aortic coarctation (CoA) before surgical correction. In our previous study, we showed a significant increase of QTc-D and JTc-D in newborns with isolated severe aortic coarctation, electrocardiographic parameters that clinical and experimental studies have suggested could reflect the physiological variability of regional and ventricular repolarization and could provide a substrate for life-threatening ventricular arrhythmias. The aim of the current study was to evaluate the effect of surgical repair of CoA on QTc-d, JTc-d in severe aortic coarctation newborns with no associated congenital cardiac malformations. The study included 30 newborns (18M; 70+/-12 h old) affected by severe congenital aortic coarctation, without associated cardiac malformations. All newborns underwent to classic extended end-to-end repair. Echocardiographic and electrocardiographic measurements were performed in each patient 24 h before and 24 h after the interventional procedure and at the end of the follow-up period, 1 month after the surgical correction. All patients at baseline, 24 h and one month after CoA surgical repair did not significantly differ in terms of heart rate, weight, height, and echocardiographic parameters. There were no statistically significant differences in QTc-D (111.7+/-47.4 vs 111.9+/-63.8 ms vs 108.5+/-55.4 ms; P=0.4) and JTc-D (98.1+/-41.3 vs 111.4+/-47.5 vs 105.1+/-33.4 ms; P=0.3) before, 24 h and 1 month after CoA surgical correction. In conclusions, our study did not show a statistically significant decrease in QTc-D and JTc-D, suggesting the hypothesis that the acute left ventricular afterload reduction, related to successful CoA surgical correction, may not reduce the ventricular electrical instability in the short-term follow-up.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты