MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpeds.2007.02.012

Медицинская библиотека · The Journal of pediatrics · 2007

Interobserver reliability and accuracy of cranial ultrasound scanning interpretation in premature infants.

Hintz Susan R, Slovis Thomas, Bulas Dorothy, Van Meurs Krisa P, Perritt Rebecca, Stevenson David K, Poole W Kenneth, Das Abhik, Higgins Rosemary D, NICHD Neonatal Research Network

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To assess interobserver reliability between 2 central readers of cranial ultrasound scanning (CUS) and accuracy of local, compared with central, interpretations.

STUDY

DESIGN

The study was a retrospective analysis of CUS data from the National Institute of Child Health and Human Development (NICHD) trial of inhaled nitric oxide for premature infants. Interobserver reliability of 2 central readers was assessed with kappa or weighted kappa. Accuracy of local, compared with central, interpretations was assessed by using sensitivity and specificity.

RESULTS

CUS from 326 infants had both central reader and local interpretations. Central reader agreement for grade 3/4 intraventricular hemorrhage (IVH), grade 3/4 IVH or periventricular leukomalacia (PVL), grade of IVH, and degree of ventriculomegaly was very good (kappa = 0.84, 0.81, 0.79, and 0.75, respectively). Agreement was poor for lower grade IVH and for PVL alone. Local interpretations were highly accurate for grade 3/4 IVH or PVL (sensitivity, 87%-90%; specificity, 92%-93%), but sensitivity was poor-to-fair for grade 1/2 IVH (48%-68%) and PVL (20%-44%).

CONCLUSIONS

Our findings demonstrate reliability and accuracy of highly unfavorable CUS findings, but suggest caution when interpreting mild to moderate IVH or white matter injury.

Для цитирования: Hintz Susan R, Slovis Thomas, Bulas Dorothy, Van Meurs Krisa P, Perritt Rebecca, Stevenson David K, Poole W Kenneth, Das Abhik, Higgins Rosemary D, NICHD Neonatal Research Network. Interobserver reliability and accuracy of cranial ultrasound scanning interpretation in premature infants.. The Journal of pediatrics. 2007. DOI: 10.1016/j.jpeds.2007.02.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.